HOME > Products > Reverse Osmosis > Residential |
|
|
|
|
|
|
Water is one of the most essential elements for sustaining human life. However, we face health risks from exposure to microbial & various contaminants that may be present in the water we drink. With the use of CSM’s Residential RO Membranes, 100% of viruses and over 99% of chemical substances are removed meaning we can enjoy clean, great tasting and most importantly safe water at home.
|
|
|
Model |
Flow Rate (GPD,L/day) |
Salt Rejection (%) |
Diameter/ Length (inch) |
Test Conditions |
Spec Sheet |
RE3512-900 |
900 (3,407) |
95.0 |
3.5 / 12 |
Household Standard at 80 psi, 40% Recovery |
|
RE3512-TK |
600 (2,271) |
95.0 |
3.5 / 12 |
Dry Integrity Test |
|
RE3012-800 |
800 (3,028) |
96.0 |
3.5 / 12 |
Household Standard at 80 psi, 40% Recovery |
|
RE3012-500 |
500 (1,893) |
97.0 |
3.0 / 12 |
Dry Integrity Test |
|
RE2812-450 |
450 (1,703) |
96.0 |
2.8 / 12 |
Household Standard |
|
RE2812-300* |
350 (1,325) |
97.0 |
2.8 / 12 |
Household Standard |
|
RE2812-HR+* |
300 (1,136) |
99.0 |
2.8 / 12 |
Household Standard |
|
RE2812-CE |
220 (833) |
97.0 |
2.8 / 12 |
Household Standard |
|
RE2012-400* |
400 (1,514) |
96.0 |
2.0 / 12 |
Household Standard at 80 psi |
|
RE2012-150 |
150 (567.8) |
98.0 |
2.0 / 12 |
Household Standard |
|
RE2012-100 |
110 (416) |
98.0 |
2.0 / 12 |
Household Standard |
|
RE2012-LPF |
60 (227) |
93.0 |
2.0 / 12 |
Household LP |
|
RE2012-LP* |
50 (189) |
93.0 |
2.0 / 12 |
Household LP |
|
RE1812-80* |
100 (379) |
98.0 |
1.8 / 12 |
Household Standard |
|
NE1812-70 |
90 (341) |
40-70 (95%) |
1.8 / 12 |
NF Household Standard |
|
RE1812-HR+* |
80 (303) |
99.0 |
1.8 / 12 |
Household Standard |
|
RE1812-50* |
70 (265) |
98.0 |
1.8 / 12 |
Household Standard |
|
RE1812-LP |
30 (114) |
93.0 |
1.8 / 12 |
Household LP |
|
RE1812-60* |
80 (303) |
98.0 |
1.8 / 12 |
Household Standard |
|
RE1810-80* |
80 (303) |
98.0 |
1.8 / 10 |
Household Standard |
|
|
|
|
|
|
Model |
Flow Rate (GPD,m3/d) |
Molecular Weight Cut Off (MWCO) |
Diameter/ Length (inch) |
Test Conditions |
Spec Sheet |
UE1810* |
200 (757) |
100K |
1.8 / 10 |
20 psi, Pure Water |
|
UE2010* |
450 (1,703) |
100K |
2.0 / 10 |
20 psi, Pure Water |
|
|
|
|
|
Household Standard test conditions: NaCl 200 mg/L, Pressure 60 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15% |
Household LP test conditions: NaCl 100 mg/L, Pressure 20 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15% |
Dry Integrity test conditions: NaCl 200 mg/L, Pressure 60~80 psig, Temperature 25°C, pH 6.5-7.0 Recovery 30~40% |
NF Household Standard test conditions: MgSO4/NaCl 250 mg/L, Pressure 60 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15% |
The stated data were obtained after 30 minutes of operation |
|
|
|
* These models are tested and certified by NSF to NSF/ANSI/CAN 61.
For more certification details,
|
|
|
|
|