Water is one of the most essential elements for sustaining human life. However, we face health risks from exposure to microbial & various contaminants that may be present in the water we drink. With the use of CSM’s Residential RO Membranes, 100% of viruses and over 99% of chemical substances are removed meaning we can enjoy clean, great tasting and most importantly safe water at home.
Model Flow Rate
(GPD,L/day)
Salt Rejection (%) Diameter/
Length (inch)
Test Conditions Spec Sheet
RE3512-900 900 (3,407) 95.0 3.5 / 12 Household Standard at 80 psi, 40% Recovery
RE3512-TK 600 (2,271) 95.0 3.5 / 12 Dry Integrity Test
RE3012-800 800 (3,028) 96.0 3.5 / 12 Household Standard at 80 psi, 40% Recovery
RE3012-500 500 (1,893) 97.0 3.0 / 12 Dry Integrity Test
RE2812-450 450 (1,703) 96.0 2.8 / 12 Household Standard
RE2812-300* 350 (1,325) 97.0 2.8 / 12 Household Standard
RE2812-HR+* 300 (1,136) 99.0 2.8 / 12 Household Standard
RE2812-CE 220 (833) 97.0 2.8 / 12 Household Standard
RE2012-400* 400 (1,514) 96.0 2.0 / 12 Household Standard at 80 psi
RE2012-150 150 (567.8) 98.0 2.0 / 12 Household Standard
RE2012-100 110 (416) 98.0 2.0 / 12 Household Standard
RE2012-LPF 60 (227) 93.0 2.0 / 12 Household LP
RE2012-LP* 50 (189) 93.0 2.0 / 12 Household LP
RE1812-80* 100 (379) 98.0 1.8 / 12 Household Standard
NE1812-70 90 (341) 40-70 (95%) 1.8 / 12 NF Household Standard
RE1812-HR+* 80 (303) 99.0 1.8 / 12 Household Standard
RE1812-50* 70 (265) 98.0 1.8 / 12 Household Standard
RE1812-LP 30 (114) 93.0 1.8 / 12 Household LP
RE1812-60* 80 (303) 98.0 1.8 / 12 Household Standard
RE1810-80* 80 (303) 98.0 1.8 / 10 Household Standard
Model Flow Rate
(GPD,m3/d)
Molecular Weight
Cut Off (MWCO)
Diameter/
Length (inch)
Test Conditions Spec Sheet
UE1810* 200 (757) 100K 1.8 / 10 20 psi, Pure Water
UE2010* 450 (1,703) 100K 2.0 / 10 20 psi, Pure Water
Household Standard test conditions: NaCl 200 mg/L, Pressure 60 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15%
Household LP test conditions: NaCl 100 mg/L, Pressure 20 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15%
Dry Integrity test conditions: NaCl 200 mg/L, Pressure 60~80 psig, Temperature 25°C, pH 6.5-7.0 Recovery 30~40%
NF Household Standard test conditions: MgSO4/NaCl 250 mg/L, Pressure 60 psig, Temperature 25°C, pH 6.5-7.0 Recovery 15%
The stated data were obtained after 30 minutes of operation
* These models are tested and certified by NSF to NSF/ANSI/CAN 61.
  For more certification details,